- Flow Measurement
- Flow Control
- Level Measurement
- Pressure Measurement
- Water Analytical
- Gas Detectors & Gas Analyzers
- I/O Components, Recorders & Automation Components
- Fittings & Valves
Dreshler Resources Sdn Bhd
17B, Jalan Perai Jaya 4,
Bandar Perai Jaya,
13700 Perai,
Penang, Malaysia.
+6019-475 8268
+6019-478 8268
+6019-478 8268
Loop Powered Velocity Sensor - MicroFlow-i
Previous | 3 / 6 | Next |
Loop Powered Velocity Sensor - MicroFlow-i
The extremely low power consumption of the MicroFlow-i makes it an ideal monitoring solution to remote sewer network access points that are difficult to reach and often have no mains power supply. These lightweight and compact sensors are ideal for spill monitoring, sewer network monitoring, sanitary sewer overflows, and event duration monitoring.
The MicroFlow-i delivers accurate, repeatable velocity measurement for liquid flow, either as an individual sensor or by providing HART communication protocol or a 4-20mA loop-powered signal into an accompanying data logging system.
_____________________________________________________________________________________________________________________________________________________________
TECHNICAL SPECIFICATIONS:
General Specifications | |
---|---|
Spec name: | Description: |
Sensor Body Dimensions: | 90 mm x 140 mm (3.54 in x 5.51 in) |
Weight: | 1 kg (2.2 lbs) |
Sensor Body Material: | Valox 357 |
Maximum Separation: | Up to 1,000 m (3,280 ft) |
Max. and Min Temperature (Electronics): | -20 °C to +60 °C (-4 °F to +140 °F) |
Velocity Range: | 0.2 m/s to 6 m/s (0.66 ft/s to 19.7 ft/s) |
Optimum Installation: | Install and an angle of 45° in line with the flow. More information is available in the manual. |
Outputs: | HART and 4-20mA loop powered |